Can each channel of ADCs in the NuMicro® family microcontrollers with the same module be sampled simultaneously?  Issue Date:2017-02-02

No, simultaneous sampling of multiple channels are not supported by ADCs with the same module. However, the NuMicro® M0519 series supports two ADC modules that can simultaneously sample channels from different modules.

For example, in the NuMicro® M451 series:
When AVDD works at 4.5V - 5.5V, the maximum ADC clock frequency is up to 20 MHz, and it needs 20 ADC clocks to complete an A/D conversion.
Thus, the minimum sampling frequency interval for each channel of the ADC is 1 uS. 

Products: Microcontrollers ,8bit 8051 MCUs ,Low Pin Count 8051 Series ,Standard 8051 Series ,Arm Cortex-M0 MCUs ,M051 Base Series ,M0518 Series ,M0519 Series ,Mini51 Base Series ,Nano100/102 Base Series ,Nano103 Base Series ,Nano110/112 LCD Series ,Nano120 USB Series ,Nano130 Advanced Series ,NUC029 Series ,NUC100/200 Advanced Series ,NUC120/122/123/220 USB Series ,NUC130/230 CAN Series ,NUC131/NUC1311 CAN Series ,NUC140/240 Connectivity Series ,Arm Cortex-M4 MCUs ,M451 Base Series ,M451M Series ,M452 USB Series ,M453 CAN Series ,M4TK Touch Key Series ,NUC442/472 Series ,NUC505 Series