FAQ
- M051 Base Series(95)
- M0518 Series(97)
- M0519 Series(43)
- M0564 Series(1)
- Mini51 Base Series(90)
- Nano100/102 Base Series(101)
- Nano103 Base Series(10)
- Nano110/112 LCD Series(100)
- Nano120 USB Series(111)
- Nano130 Advanced Series(110)
- NUC029 Series(94)
- NUC100/200 Advanced Series(102)
- NUC120/122/123/220 USB Series(116)
- NUC121/125 Series(1)
- NUC126 USB Series(2)
- NUC130/230 CAN Series(103)
- NUC131/NUC1311 CAN Series(98)
- NUC140/240 Connectivity Series(114)
- M451 Base Series(118)
- M451M Series(117)
- M452 USB Series(130)
- M4521 USB Series(1)
- M453 CAN Series(128)
- M463 CAN FD/USB HS Series(1)
- M467 Ethernet/Crypto Series(1)
- M471 Series(1)
- M479 Motor Control Series(1)
- M481 Base Series(4)
- M482 USB FS OTG Series(4)
- M483 CAN Series(4)
- M484 USB HS OTG Series(4)
- M485 Crypto Series(4)
- M487 Ethernet Series(4)
- M4TK Touch Key Series(25)
- NUC442/472 Series(130)
- NUC472 Series(1)
- NUC505 Series(138)
Products
Applications
Function
+
FAQ
What needs to be considered when switching clock sources? Issue Date:2015-04-01
Before clock switching, both the pre-selected and newly selected clock sources must be stable. The pre-selected clock source can be turned off after the switching is complete.
The register CLKSTATUS maintains the state of each clock source. User may read the CLKSTATUS value to determine if the clock source is stable.
Products: | Microcontrollers ,Arm Cortex-M0 MCUs ,M051 Base Series ,M0518 Series ,Mini51 Base Series ,Nano100/102 Base Series ,Nano110/112 LCD Series ,Nano120 USB Series ,Nano130 Advanced Series ,NUC029 Series ,NUC100/200 Advanced Series ,NUC120/122/123/220 USB Series ,NUC130/230 CAN Series ,NUC131/NUC1311 CAN Series ,NUC140/240 Connectivity Series ,Arm Cortex-M4 MCUs ,M451 Base Series ,M451M Series ,M452 USB Series ,M453 CAN Series ,NUC442/472 Series ,NUC505 Series |
---|---|
Applications: | |
Function: | Peripherals,Clock Control,HIRC,HXT,LIRC,LXT,PLL |